BTA06GP
器件描述:TRIACS
文件大小:59.73KB,共4页
Sponsor by e络盟
器件资料摘要:
BTA06 GP
March 1995
TRIACS
Symbol Parameter Value Unit
I
T(RMS)
RMS on-state current
(360° conduction angle)
Tc = 105 °C6 A
I
TSM
Non repetitive surge peak on-state current
( Tj initial = 25°C)
tp = 8.3 ms 105 A
tp = 10 ms 100
I
2
tI
2
t value tp = 10 ms 50 A
2
s
dI/dt Critical rate of rise of on-state current
Gate supply : I
G
= 500mA di
G
/dt = 1A/µs
Repetitive
F = 50 Hz
10 A/µs
Non
Repetitive
50
Tstg
Tj
Storage and operating junction temperature range - 40 to + 150
- 40 to + 125
°C
°C
Tl Maximum lead temperature for soldering during 10 s at 4.5 mm
from case
260 °C
TO220AB
(Plastic)
A1
A2
G
.LOW I
H
= 13mA max
.HIGH SURGE CURRENT : I
TSM
= 100A
.I
GT
SPECIFIED IN FOUR QUADRANTS
.INSULATING VOLTAGE = 2500V
(RMS)
(UL RECOGNIZED : E81734)
DESCRIPTION
Symbol Parameter BTA06- Unit
400 GP 600 GP
V
DRM
V
RRM
Repetitive peak off-state voltage
Tj = 125 °C
400 600 V
ABSOLUTE RATINGS (limiting values)
FEATURES
The BTA06 GP’s use high performance, glass pas-
sivated chips.
The insulated TO220AB package, the high surge
current and low holding current make this family
well adapted to LIGHT DIMMER applications.
1/4