235
器件描述:Axial Lead and Cartridge Fuses - Designed to UL/CSA Standards
文件大小:145.61KB,共2页
Sponsor by e络盟
器件资料摘要:
Axial Lead and Cartridge Fuses
424
www.littelfuse.com
Designed to UL/CSA Standards
5 x 20 mm Fast-Acting Fuse 235 Series
ELECTRICAL CHARACTERISTICS:
% of Ampere Opening
Rating Time
100% 4 hours, Minimum
135% 1 hour, Maximum
200% 5 second, Maximum
INTERRUPTING RATING:
0.10-1A 10,000 amperes at 125 VAC, 0.7-0.8 power factor
35 amperes at 250 VAC, 0.7-0.8 power factor
1.25A-3.15A 10,000 amperes at 125 VAC, 0.7-0.8 power factor
100 amperes at 250 VAC, 0.7-0.8 power factor
4A-6A 10,000 amperes at 125 VAC, 0.7-0.8 power factor
ORDERING INFORMATION:
RoHS compliant and Pb-free version available, add XP suffix to
standard catalog number
• Designed to UL/CSA/ANCE 248 Standard.
• Available in Cartridge and Axial Lead Format.
• Available in ratings of 0.100 to 6 amperes.
• RoHS compliant and Pb-free version available, add XP suffix to
standard catalog number
Nominal Nominal
Catalog Ampere Voltage Resistance Melting I
2
t
Number Rating Rating Cold Ohms A
2
Sec.
235.100 .100 250 8.40 0.00160
235.125 .125 250 5.75 0.00280
235.200 .200 250 3.15 0.00890
235.250 .250 250 2.25 0.0170
235.300 .300 250 1.60 0.0330
235.400 .400 250 1.08 0.0600
235.500 .500 250 0.455 0.0710
235.600 .600 250 0.318 0.115
235.700 .700 250 0.263 0.160
235.800 .800 250 0.195 0.260
235 001 1 250 0.153 0.480
235 1.25 1.25 250 0.106 1.12
235 01.6 1.6 250 0.0775 2.08
235 002 2 250 0.0600 2.72
235 02.5 2.5 250 0.0438 5.59
235 003 3 250 0.0348 8.62
235 004 4 125 0.0248 17.60
235 005 5 125 0.0185 28.15
235 006 6 125 0.0150 48.60
®
U
L ®
RoHS
ENVIRONMENTAL SPECIFICATIONS:
Operating temperature: -55˚C to 125˚C
Thermal Shock: MIL-STD-202F Method 107G, Test Condition B: (5
cycles –65°C to +125°C)
Vibration: MIL-STD-202F Method 201A
Humidity: MIL-STD-202F Method 103B, Test Condition A. high relative
humidity (95%) and elevated temperature (40°C) for 240 hours.
Salt Spray: MIL-STD-202F Method 101D, Test Condition B
PHYSICAL SPECIFICATIONS:
Material: Body: Glass
Cap: Nickel Plated Brass
Leads: Tin Plated Copper
Terminal Strength: MIL-STD-202F Method 211A,
Test Condition A
Solderability: Reference IEC 60127 Second Edition 2003-01 Annex A
Terminal strength: MIL-STD-202F Method 211A, Test Condition A
Product Marking: Cap 1: current and voltage rating.
Cap 2: Agency approval markings.
Packaging: Available in Bulk (v=5, H=100, M=1000 pcs/pkg) or on
Tape/Reel (MRET1=1000 pcs/reel).
Pb