20NAB06
器件描述:3-phase bridge rectifier +braking chopper +3-phase bridge inverter
文件大小:246.83KB,共4页
Sponsor by e络盟
器件资料摘要:
© by SEMIKRON 000131 B 16 – 53
Absolute Maximum Ratings
Symbol Conditions
1)
Values Units
Inverter & Chopper
V
CES
V
GES
I
C
I
CM
I
F
= –I
C
I
FM
= –I
CM
T
heatsink
= 25 / 80 °C
t
p
< 1 ms; T
heatsink
= 25 / 80 °C
T
heatsink
= 25 / 80 °C
t
p
< 1 ms; T
heatsink
= 25 / 80 °C
1200
± 20
23 / 15
46 / 30
24 / 17
48 / 34
V
V
A
A
A
A
Bridge Rectifier
V
RRM
I
D
I
FSM
I
2
t
T
heatsink
= 80 °C
t
p
= 10 ms; sin. 180 °, T
j
= 25 °C
t
p
= 10 ms; sin. 180 °, T
j
= 25 °C
1500
25
700
2400
V
A
A
A
2
s
T
j
T
stg
V
isol
AC, 1 min.
– 40 . . . + 150
– 40 . . . + 125
2500
°C
°C
V
Characteristics
Symbol Conditions
1)
min. typ. max. Units
IGBT - Inverter & Chopper
V
CEsat
t
d(on)
t
r
t
d(off)
t
f
E
on
+ E
off
C
ies
R
thjh
I
C
= 15 A T
j
= 25 (125) °C
V
CC
= 600 V; V
GE
= ± 15 V
I
C
= 15 A; T
j
= 125 °C
R
gon
= R
goff
= 82 Ω
inductive load
V
CE
= 25 V; V
GE
= 0 V, 1 MHz
per IGBT
–
–
–
–
–
–
–
–
2,5(3,1)
55
45
400
70
4,0
1,0
–
3,0(3,7)
110
90
600
100
–
–
1,4
V
ns
ns
ns
ns
mJ
nF
K/W
Diode
2)
- Inverter & Chopper
V
F
= V
EC
V
TO
r
T
I
RRM
Q
rr
E
off
R
thjh
I
F
= 15 A T
j
= 25 (125) °C
T
j
= 125 °C
T
j
= 125 °C
I
F
= 15 A, V
R
= – 600 V
di
F
/dt = – 400 A/µs
V
GE
= 0 V, T
j
= 125 °C
per diode
–
–
–
–
–
–
–
2,0(1,8)
1,0
53
16
2,7
0,6
–
2,5(2,3)
1,2
73
–
–
–
1,7
V
V
mΩ
A
µC
mJ
K/W
Diode - Rectifier
V
F
R
thjh
I
F
= 35 A, T
j
= 25 °C
per diode
–
–
1,2
–
–
1,6
V
K/W
Temperature Sensor
R
TS
T = 25 / 100 °C 1000 / 1670 Ω
Shunts (SKiiP 22 NAB 12 I)
R
cs(dc)
R
cs(ac)
5 %
4)
1 %
16,5
10
mΩ
mΩ
Mechanical Data
M
1
Case
case to heatsink, SI Units
mechanical outline see page
B 16 – 8
2–
M2
2,5 Nm
SKiiP 22 NAB 12 - SKiiP 22 NAB 12 I MiniSKiiP 2
SEMIKRON integrated
intelligent Power
SKiiP 22 NAB 12
SKiiP 22 NAB 12 I
3)
3-phase bridge rectifier +
braking chopper +
3-phase bridge inverter
Case M2
UL recognized file no. E63532
specification of shunts and
temperature sensor see part A
common characteristics see
page B 16 – 4
1)
T
heatsink
= 25 °C, unless
otherwise specified
2)
CAL = Controlled Axial Lifetime
Technology (soft and fast
recovery)
3)
With integrated DC and/or AC
shunts
4)
accuracy of pure shunt, please
note that for DC shunt no
separate sensing contact is
used.