BT136D
器件描述:TRIAC
文件大小:184.7KB,共4页
Sponsor by e络盟
器件资料摘要:
TRIAC BT136D
TO-220
Plastic Package
For use in General Purpose Bidirectional Switching and Phase Control Applications
ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITION UNIT
Repetitive Peak Off State Voltage VDRM V
RMS on State Current IT (RMS) full sine wave, Tmb <107ºC A
Non Repetitive Peak on State Current ITSM full sine wave, TJ=25ºC prior to Surge
t=20ms A
t=16.7ms A
l2t for Fusing I2t t=10ms A2s
Repetitive Rate of Rise of on State
Current After Triggering dlT/dt
ITM=6A, IG=0.2A,
dlG/dt=0.2A/µs
T2+ G+ A/µs
T2+ G- A/µs
T2- G- A/µs
T2- G+ A/µs
Peak Gate Current IGM A
Peak Gate Voltage VGM V
Peak Gate Power PGM W
Average Gate Power PG (AV) Over any 20ms period W
Storage Temperature Tstg - 40 to 150 ºC
Operating Junction Temperature Tj ºC
THERMAL RESISTANCE
Junction to Mounting Base Rth (j-mb) full cycle K/W
half cycle K/W
Junction to Ambient Rth (j-a) in free air K/W
ELECTRICAL CHARACTERISTICS (TJ=25ºC unless specified otherwise)
PARAMETER SYMBOL TEST CONDITION MIN MAX UNIT
Gate Trigger Current IGT VD=12V, IT=0.1A
T2+ G+ 5.0 mA
T2+ G- 5.0 mA
T2- G- 5.0 mA
T2- G+ 10 mA
BT136DRev030205E
60 typ
125
3.0 max
3.7 max
2.0
5.0
5.0
0.5
50
50
50
10
27
3.1
VALUE
600
4.0
25
T1
G
T2
Continental Device India Limited Data Sheet Page 1 of 4
Continental Device India Limited
An ISO/TS 16949, ISO 9001 and ISO 14001 Certified Company