ATH30
器件描述:30Amps
文件大小:647.54KB,共2页
Sponsor by e络盟
器件资料摘要:
North America (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211Asia (HK): 852-2437-96622
Special Features
Electrical Specs
30Amps
• Point-of-Load Alliance product
• Open frame TH or SMT termination
• Auto-Track™ Sequencing
• Margin Up/Down Controls
• Remote sense compensation
• Output Voltage Adjust (Resistor Programming)
• Under Voltage Lockout
• Pre-Biased start-up
• Output On/Off Inhibit
• -40°C to +85°C Ambient Air Operation
• Non Isolated module
Input
Input Range 3.0 - 3.6V
4.5 - 5.5V
10.8 - 13.2V
Under Voltage Lockout with hysterisis
Efficiency up to 94%
Output
Overall Regulation 1% of Vo Typ
Noise/Ripple 40mV Typ (2.5Vo and below)
1% Vo Typ (Vo > 2.5V)
Remote sense Up to 300mV max
Transient Response 100mV typical for 3.3Vo
for 50% to 100% IO,MAX step change
70us recovery time (Co = 330uF)
Over Current Protection 155% IO,MAX typical (autorecovery)
Control
Inhibit Control Negative Logic
(OPEN = Normal Operation)
(GROUND = Function Active)
Output Voltage Adjust See output range on page 2
Output Margin ±5% VO,NOM
Output Auto-Track™ (See Note 5)
Specifications subject to change without notice
Ambient air operating temperature range:
-40°C to +85°C
Storage temperature: -40°C to +125°C
Demonstrated MTBF: 3.9M Hrs
UL, cUL 60950 Recognition
EN 60950 though TUV or VDE (Pending)
Environmental
Total Power: 143W
Input Voltages: 3.3V, 5V, 12V
No. of Outputs: Single
Safety
ATH30